Name Planned shipping method Start Date  
Electrical disturbances - Absorber-lined shielded enclosure ISO 11452-2
Parameters (quantitative): Amplitude [V/m] at different frequencies
Article Number: 2011084
Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 200 MHz - 6 GHz | Limit value / test level: up to 100 V/m
Category: physical mechanical testing material testing electromagnetic compatibility
Accreditation: This proficiency test is not included in the scope of the accreditation.
additional test chambers or additional test places are charged with 50% of the proficiency testing price
Shipping at room temperature August 2026 Add to cart
Electrical disturbances - Absorber-lined shielded enclosure ISO 11452-2
Article Number: 2011084
August 2027 Add to cart
Electrical fast transient immunity IEC 61000-4-4
Parameters (quantitative): Amplitude at L (+ 2000 Vpk) - Minimum value [Vpeak], Amplitude at N (+ 2000 Vpk) - Minimum value [Vpeak], Amplitude at PE (+ 2000 Vpk) - Minimum value [Vpeak], Amplitude at L (+ 2000 Vpk) - Maximum value [Vpeak], Amplitude at L (- 2000 Vpk) - Minimum value [Vpeak], Amplitude at N (- 2000 Vpk) - Minimum value [Vpeak], Amplitude at PE (- 2000 Vpk) - Minimum value [Vpeak], Amplitude at L (- 2000 Vpk) - Maximum value [Vpeak], Pulse Width - Mean value [ns], Burst Packet length - Mean value [ms], Burst Period - Mean value [ms]
Article Number: 2011057
Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface.
Category: physical mechanical testing material testing electromagnetic compatibility
Accreditation: This proficiency test is not included in the scope of the accreditation.
additional test chambers or additional test places are charged with 50% of the proficiency testing price
Shipping at room temperature May 2026 Add to cart
Electrical fast transient immunity IEC 61000-4-4
Article Number: 2011057
May 2027 Add to cart
Electrostatic discharge (powered-up direct discharges) ISO 10605 (8.3)
Article Number: 2011249
Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface.
Category: physical mechanical testing material testing electromagnetic compatibility
Accreditation: This proficiency test is not included in the scope of the accreditation.
Shipping at room temperature May 2026 Add to cart
Electrostatic discharge (powered-up direct discharges) ISO 10605 (8.3)
Article Number: 2011249
May 2027 Add to cart
Electrostatic discharge immunity IEC 61000-4-2
Parameters (quantitative): Amplitude (+ 8 kV) - Maximum value [Vpeak], Amplitude (+ 8 kV) - Minimum value [Vpeak], Amplitude (- 8 kV) - Maximum value [Vpeak], Amplitude (- 8 kV) - Minimum value [Vpeak], Pulse Width (+ 8 kV) - Mean value [ns], Pulse Width (- 8 kV) - Mean value [ns]
Article Number: 2011055
Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface.
Category: physical mechanical testing material testing electromagnetic compatibility
Accreditation: This proficiency test is not included in the scope of the accreditation.
additional test chambers or additional test places are charged with 50% of the proficiency testing price
Is currently underway. Can still be booked.
Shipping at room temperature August 2025 Add to cart
Electrostatic discharge immunity IEC 61000-4-2
Article Number: 2011055
May 2026 Add to cart
Electrostatic discharge immunity IEC 61000-4-2
Article Number: 2011055
May 2027 Add to cart
Emission of Radio Frequency Energy RTCA DO-160 (sec. 21)
Article Number: 2011065
Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 2 MHz - 6 GHz
Category: physical mechanical testing material testing electromagnetic compatibility
Accreditation: This proficiency test is not included in the scope of the accreditation.
additional test chambers or additional test places are charged with 50% of the proficiency testing price
Shipping at room temperature April 2026 Add to cart
Emission of Radio Frequency Energy RTCA DO-160 (sec. 21)
Article Number: 2011065
April 2027 Add to cart
Emission of transient conducted disturbances on supply lines ISO 7637-2 - UN ECE R10 (6.7)
Article Number: 2011244
Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: slow (ms) and fast (ns und μs) pulses
Category: physical mechanical testing material testing electromagnetic compatibility
Accreditation: This proficiency test is not included in the scope of the accreditation.
Is currently underway. Can still be booked.
Shipping at room temperature October 2025 Add to cart
Emission of transient conducted disturbances on supply lines ISO 7637-2 - UN ECE R10 (6.7)
Article Number: 2011244
October 2026 Add to cart
Emission of transient conducted disturbances on supply lines ISO 7637-2 - UN ECE R10 (6.7)
Article Number: 2011244
October 2027 Add to cart
Immunity - conducted disturbances (radio-frequency fields) IEC 61000-4-6
Parameters (quantitative): Amplitude [Vrms] at different frequencies
Article Number: 2011059
Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface.
Category: physical mechanical testing material testing electromagnetic compatibility
Accreditation: This proficiency test is not included in the scope of the accreditation.
additional test chambers or additional test places are charged with 50% of the proficiency testing price
Shipping at room temperature May 2026 Add to cart
Immunity - conducted disturbances (radio-frequency fields) IEC 61000-4-6
Article Number: 2011059
May 2027 Add to cart
Immunity (ESA) - bulk current injection (BCI) ISO 11452-4 - UN ECE R10 (6.8)
Article Number: 2011245
Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 10 kHz - 400 MHz
Category: physical mechanical testing material testing electromagnetic compatibility
Accreditation: This proficiency test is not included in the scope of the accreditation.
Is currently underway. Can still be booked.
Shipping at room temperature October 2025 Add to cart
Immunity (ESA) - bulk current injection (BCI) ISO 11452-4 - UN ECE R10 (6.8)
Article Number: 2011245
October 2026 Add to cart
Immunity (ESA) - bulk current injection (BCI) ISO 11452-4 - UN ECE R10 (6.8)
Article Number: 2011245
October 2027 Add to cart
Immunity (ESA) - electromagnetic radiation - free field UN ECE R10 (6.8)
Parameters (quantitative): Amplitude [V/m] at different frequencies
Article Number: 2011085
Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 20 MHz - 2000 MHz | Limit value / test level: 30 V/m
Category: physical mechanical testing material testing electromagnetic compatibility
Accreditation: This proficiency test is not included in the scope of the accreditation.
additional test chambers or additional test places are charged with 50% of the proficiency testing price
Shipping at room temperature August 2026 Add to cart
1 Parameters with this label depend on the number of participants and/or the choice of materials.
Under certain circumstances, this parameter may not be available in the proficiency test.