Broadband and narrowband electromagnetic interference (ESA) - UN ECE R10 (6.5, 6.6)
Parameters (quantitative): max. field strength [dBµV/m] in different frequency ranges (BB and NB)
Article Number: 2011074
Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 30 MHz - 1 GHz (BB and NB)
Category: physical mechanical testing material testing electromagnetic compatibility
Accreditation: This proficiency test is not included in the scope of the accreditation.
additional test chambers or additional test places are charged with 50% of the proficiency testing price
Shipping at room temperature August 2025 Add to cart
Broadband and narrowband electromagnetic interference (ESA) - UN ECE R10 (6.5, 6.6)
Article Number: 2011074
August 2026 Add to cart
CISPR 16-2-1 - EN 55016-2-1 - EN 55011
Parameters (quantitative): max. voltage level [dB (µV)] in different frequency ranges
Article Number: 2011054
Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 150 kHz - 30 MHz
Category: physical mechanical testing material testing electromagnetic compatibility
Accreditation: This proficiency test is not included in the scope of the accreditation.
additional test chambers or additional test places are charged with 50% of the proficiency testing price
Shipping at room temperature May 2025 Add to cart
CISPR 16-2-1 - EN 55016-2-1 - EN 55011
Article Number: 2011054
May 2026 Add to cart
CISPR 16-2-3 - EN 55016-2-3 - EN 55011
Parameters (quantitative): max. field strength [dBµV/m] in different frequency ranges
Article Number: 2010931
Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 30 MHz - 6 GHz Antenna distance 3 m, (EN 55011 up to 1 GHz)
Category: physical mechanical testing material testing electromagnetic compatibility
Accreditation: This proficiency test is not included in the scope of the accreditation.
additional test chambers or additional test places are charged with 50% of the proficiency testing price
Shipping at room temperature April 2025 Add to cart
CISPR 16-2-3 - EN 55016-2-3 - EN 55011
Article Number: 2010931
April 2026 Add to cart
Conducted disturbances CISPR 25
Article Number: 2011240
Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 150 kHz - 108 MHz
Category: physical mechanical testing material testing electromagnetic compatibility
Accreditation: This proficiency test is not included in the scope of the accreditation.
New proficiency testing
Shipping at room temperature October 2025 Add to cart
Conducted disturbances CISPR 25
Article Number: 2011240
October 2026 Add to cart
Conducted emissions, audio frequency currents, power leads MIL-STD461 (CE101)
Article Number: 2011242
Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 30 Hz - 10 kHz
Category: physical mechanical testing material testing electromagnetic compatibility
Accreditation: This proficiency test is not included in the scope of the accreditation.
New proficiency testing
Shipping at room temperature October 2025 Add to cart
Conducted emissions, audio frequency currents, power leads MIL-STD461 (CE101)
Article Number: 2011242
October 2026 Add to cart
Conducted emissions, audio frequency currents, power leads MIL-STD461 (CE102)
Article Number: 2011243
Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 10 kHz - 10 MHz
Category: physical mechanical testing material testing electromagnetic compatibility
Accreditation: This proficiency test is not included in the scope of the accreditation.
New proficiency testing
Shipping at room temperature October 2025 Add to cart
Conducted emissions, audio frequency currents, power leads MIL-STD461 (CE102)
Article Number: 2011243
October 2026 Add to cart
Conducted RF emissions RTCA DO-160 (sec. 21)
Article Number: 2011241
Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 10 kHz - 200 MHz
Category: physical mechanical testing material testing electromagnetic compatibility
Accreditation: This proficiency test is not included in the scope of the accreditation.
New proficiency testing
Shipping at room temperature October 2025 Add to cart
Conducted RF emissions RTCA DO-160 (sec. 21)
Article Number: 2011241
October 2026 Add to cart
Conducted Susceptibility (BCI) RTCA DO-160 (sec. 20)
Article Number: 2011246
Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 10 kHz - 400 MHz
Category: physical mechanical testing material testing electromagnetic compatibility
Accreditation: This proficiency test is not included in the scope of the accreditation.
New proficiency testing
Shipping at room temperature October 2025 Add to cart
Conducted Susceptibility (BCI) RTCA DO-160 (sec. 20)
Article Number: 2011246
October 2026 Add to cart
Conducted susceptibility, bulk cable injection (BCI) MIL-STD461 (CS114)
Article Number: 2011247
Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 4 kHz - 200 MHz
Category: physical mechanical testing material testing electromagnetic compatibility
Accreditation: This proficiency test is not included in the scope of the accreditation.
New proficiency testing
Shipping at room temperature October 2025 Add to cart
Conducted susceptibility, bulk cable injection (BCI) MIL-STD461 (CS114)
Article Number: 2011247
October 2026 Add to cart
Electrical disturbances - Absorber-lined shielded enclosure ISO 11452-2
Parameters (quantitative): Amplitude [V/m] at different frequencies
Article Number: 2011084
Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 200 MHz - 6 GHz | Limit value / test level: up to 100 V/m
Category: physical mechanical testing material testing electromagnetic compatibility
Accreditation: This proficiency test is not included in the scope of the accreditation.
additional test chambers or additional test places are charged with 50% of the proficiency testing price
Shipping at room temperature August 2025 Add to cart
Electrical disturbances - Absorber-lined shielded enclosure ISO 11452-2
Article Number: 2011084
August 2026 Add to cart
1 Parameter mit dieser Kennzeichnung sind abhangig von der Teilnehmerzahl und/oder der Materialauswahl.
Unter Umständen kann es vorkommen, dass dieser Parameter im Ringversuch nicht zur Verfügung steht.