Currently set filters:

  • Free Search: 60068-2-6
Name Planned shipping method Start Date  
Vibration IEC 60068-2-6, -2-64
Parameters (quantitative): Swept sine excitation (a1) [m/s² (peak)], Swept sine excitation (a1) [log10 m/s² (peak)], Broad band random acceleration excitation (a2) [(m/s²)²/Hz], Broad band random acceleration excitation (a2) [log10 (m/s²)²/Hz], Sine resonance frequency (a3) [Hz], Swept sine excitation traverse movement (b1) [m/s² (peak)], Swept sine excitation traverse movement (b1) [log10 m/s² (peak)], Broad band random acceleration traverse movement (b2) [(m/s²)²/Hz], Broad band random acceleration traverse movement (b2) [log10 (m/s²)²/Hz], Sine resonance frequency (100 Hz) - (c1) [Hz], Sine resonance frequency (300 Hz) - (c1) [Hz]
Article Number: 2011035
Description: Qualification of the main and transverse movement with evaluation of the disturbance sensitivity as an interaction between test specimen and testing machine, Measurement of the characteristic resonance frequencies of the test specimen
Category: physical mechanical testing material testing environmental testing
Accreditation: This proficiency test is not included in the scope of the accreditation.
additional shakers are charged with 50% of the proficiency testing price
Unfortunately, no further booking is possible this year.
Shipping at room temperature February 2025
Vibration IEC 60068-2-6, -2-64
Article Number: 2011035
March 2026 Add to cart
Vibration IEC 60068-2-6, -2-64 (round 2)
Parameters (quantitative): Swept sine excitation (a1) [m/s² (peak)], Swept sine excitation (a1) [log10 m/s² (peak)], Broad band random acceleration excitation (a2) [(m/s²)²/Hz], Broad band random acceleration excitation (a2) [log10 (m/s²)²/Hz], Sine resonance frequency (a3) [Hz], Swept sine excitation traverse movement (b1) [m/s² (peak)], Swept sine excitation traverse movement (b1) [log10 m/s² (peak)], Broad band random acceleration traverse movement (b2) [(m/s²)²/Hz], Broad band random acceleration traverse movement (b2) [log10 (m/s²)²/Hz], Sine resonance frequency (100 Hz) - (c1) [Hz], Sine resonance frequency (300 Hz) - (c1) [Hz]
Article Number: 2011107
Description: Qualification of the main and transverse movement with evaluation of the disturbance sensitivity as an interaction between test specimen and testing machine, Measurement of the characteristic resonance frequencies of the test specimen
Category: physical mechanical testing material testing environmental testing
Accreditation: This proficiency test is not included in the scope of the accreditation.
additional shakers are charged with 50% of the proficiency testing price
Shipping at room temperature April 2025 Add to cart
Vibration IEC 60068-2-6, -2-64 (round 2)
Article Number: 2011107
April 2026 Add to cart
Vibration IEC 60068-2-6, -2-64 (round 3)
Parameters (quantitative): Swept sine excitation (a1) [m/s² (peak)], Swept sine excitation (a1) [log10 m/s² (peak)], Broad band random acceleration excitation (a2) [(m/s²)²/Hz], Broad band random acceleration excitation (a2) [log10 (m/s²)²/Hz], Sine resonance frequency (a3) [Hz], Swept sine excitation traverse movement (b1) [m/s² (peak)], Swept sine excitation traverse movement (b1) [log10 m/s² (peak)], Broad band random acceleration traverse movement (b2) [(m/s²)²/Hz], Broad band random acceleration traverse movement (b2) [log10 (m/s²)²/Hz], Sine resonance frequency (100 Hz) - (c1) [Hz], Sine resonance frequency (300 Hz) - (c1) [Hz]
Article Number: 2011196
Description: Qualification of the main and transverse movement with evaluation of the disturbance sensitivity as an interaction between test specimen and testing machine, Measurement of the characteristic resonance frequencies of the test specimen
Category: physical mechanical testing material testing environmental testing
Accreditation: This proficiency test is not included in the scope of the accreditation.
additional shakers are charged with 50% of the proficiency testing price
Shipping at room temperature April 2026 Add to cart
1 Parameter mit dieser Kennzeichnung sind abhangig von der Teilnehmerzahl und/oder der Materialauswahl.
Unter Umständen kann es vorkommen, dass dieser Parameter im Ringversuch nicht zur Verfügung steht.