Proficiency testing catalogue
Name | Planned shipping method | Start Date | ||
---|---|---|---|---|
Electrostatic discharge immunity IEC 61000-4-2 Parameters (quantitative): Amplitude (+ 8 kV) - Maximum value [Vpeak], Amplitude (+ 8 kV) - Minimum value [Vpeak], Amplitude (- 8 kV) - Maximum value [Vpeak], Amplitude (- 8 kV) - Minimum value [Vpeak], Pulse Width (+ 8 kV) - Mean value [ns], Pulse Width (- 8 kV) - Mean value [ns] Article Number: 2011055 Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Category: physical mechanical testing material testing electromagnetic compatibility Accreditation: This proficiency test is not included in the scope of the accreditation. additional test chambers or additional test places are charged with 50% of the proficiency testing price |
|
May 2026 | Add to cart | |
Emission of Radio Frequency Energy RTCA DO-160 (sec. 21) Article Number: 2011065 Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 2 MHz - 6 GHz Category: physical mechanical testing material testing electromagnetic compatibility Accreditation: This proficiency test is not included in the scope of the accreditation. additional test chambers or additional test places are charged with 50% of the proficiency testing price |
|
April 2026 | Add to cart | |
Emission of transient conducted disturbances on supply lines ISO 7637-2 - UN ECE R10 (6.7) Article Number: 2011244 Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: slow (ms) and fast (ns und μs) pulses Category: physical mechanical testing material testing electromagnetic compatibility Accreditation: This proficiency test is not included in the scope of the accreditation. New proficiency testing |
|
October 2025 | Add to cart | |
Emission of transient conducted disturbances on supply lines ISO 7637-2 - UN ECE R10 (6.7) Article Number: 2011244 |
October 2026 | Add to cart | ||
Immunity - conducted disturbances (radio-frequency fields) IEC 61000-4-6 Parameters (quantitative): Amplitude [Vrms] at different frequencies Article Number: 2011059 Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Category: physical mechanical testing material testing electromagnetic compatibility Accreditation: This proficiency test is not included in the scope of the accreditation. additional test chambers or additional test places are charged with 50% of the proficiency testing price |
|
May 2026 | Add to cart | |
Immunity (ESA) - bulk current injection (BCI) ISO 11452-4 - UN ECE R10 (6.8) Article Number: 2011245 Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 10 kHz - 400 MHz Category: physical mechanical testing material testing electromagnetic compatibility Accreditation: This proficiency test is not included in the scope of the accreditation. New proficiency testing |
|
October 2025 | Add to cart | |
Immunity (ESA) - bulk current injection (BCI) ISO 11452-4 - UN ECE R10 (6.8) Article Number: 2011245 |
October 2026 | Add to cart | ||
Immunity (ESA) - electromagnetic radiation - free field UN ECE R10 (6.8) Parameters (quantitative): Amplitude [V/m] at different frequencies Article Number: 2011085 Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 20 MHz - 2000 MHz | Limit value / test level: 30 V/m Category: physical mechanical testing material testing electromagnetic compatibility Accreditation: This proficiency test is not included in the scope of the accreditation. additional test chambers or additional test places are charged with 50% of the proficiency testing price |
|
August 2026 | Add to cart | |
Impulse magnetic field immunity IEC 61000-4-9 Article Number: 2011061 Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Category: physical mechanical testing material testing electromagnetic compatibility Accreditation: This proficiency test is not included in the scope of the accreditation. additional test chambers or additional test places are charged with 50% of the proficiency testing price |
|
May 2026 | Add to cart | |
MIL-STD461 (RE102) - AECTP 500 (NRE02) - VG95373-12 (SA04G) Parameters (quantitative): max. field strength [dBµV/m] in different frequency ranges Article Number: 2011066 Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 10 kHz - 18 GHz Category: physical mechanical testing material testing electromagnetic compatibility Accreditation: This proficiency test is not included in the scope of the accreditation. additional test chambers or additional test places are charged with 50% of the proficiency testing price |
|
August 2026 | Add to cart | |
MIL-STD461 (RS103) - AECTP 500 (NRS02) - VG95373-13 (SF03G) Parameters (quantitative): Amplitude [V/m] at different frequencies Article Number: 2011078 Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 10 kHz - 40 GHz | test level: 50 V/m Category: physical mechanical testing material testing electromagnetic compatibility Accreditation: This proficiency test is not included in the scope of the accreditation. additional test chambers or additional test places are charged with 50% of the proficiency testing price |
|
August 2026 | Add to cart | |
Power frequency magnetic field immunity IEC 61000-4-8 Article Number: 2011060 Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Category: physical mechanical testing material testing electromagnetic compatibility Accreditation: This proficiency test is not included in the scope of the accreditation. additional test chambers or additional test places are charged with 50% of the proficiency testing price |
|
May 2026 | Add to cart | |
Radiated emissions assemblies - Anechoic chamber CISPR 25 Parameters (quantitative): max. field strength [dBµV/m] in different frequency ranges Article Number: 2011072 Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 150 kHz - 6 GHz Category: physical mechanical testing material testing electromagnetic compatibility Accreditation: This proficiency test is not included in the scope of the accreditation. additional test chambers or additional test places are charged with 50% of the proficiency testing price |
|
August 2026 | Add to cart | |
Radiated, radio-frequency, electromagn. field immunity IEC 61000-4-3 Parameters (quantitative): Amplitude [V/m] at different frequencies Article Number: 2010933 Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 80 MHz - 6 GHz | Limit value / test level: 10 V/m, 3 V/m Category: physical mechanical testing material testing electromagnetic compatibility Accreditation: This proficiency test is not included in the scope of the accreditation. additional test chambers or additional test places are charged with 50% of the proficiency testing price |
|
April 2026 | Add to cart | |
Radio Frequency Susceptibility (Radiated) RTCA DO-160 (sec. 20) Article Number: 2011077 Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: 100 MHz - 8 GHz | test level: Cat R Category: physical mechanical testing material testing electromagnetic compatibility Accreditation: This proficiency test is not included in the scope of the accreditation. additional test chambers or additional test places are charged with 50% of the proficiency testing price |
|
April 2026 | Add to cart | |
Surge immunity IEC 61000-4-5 Parameters (quantitative): Amplitude L-PE (+ 2000 Vpk) - Minimum value [Vpeak], Amplitude N-PE (+ 2000 Vpk) - Minimum value [Vpeak], Amplitude at L-N (+ 1000 Vpk) - Minimum value [Vpeak], Amplitude L-PE (- 2000 Vpk) - Minimum value [Vpeak], Amplitude N-PE (- 2000 Vpk) - Minimum value [Vpeak], Amplitude at L-N (- 1000 Vpk) - Minimum value [Vpeak], Rise Time - Mean value [µs], Pulse Width - Mean value [µs] Article Number: 2011058 Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Category: physical mechanical testing material testing electromagnetic compatibility Accreditation: This proficiency test is not included in the scope of the accreditation. additional test chambers or additional test places are charged with 50% of the proficiency testing price Is currently underway. Can still be booked. |
|
August 2025 | Add to cart | |
Surge immunity IEC 61000-4-5 Article Number: 2011058 |
May 2026 | Add to cart | ||
Transient disturbances conducted along supply lines ISO 7637-2 - UN ECE R10 (6.9) Article Number: 2011248 Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Important test parameters: Pulse 1, 2a, 2b, 3a, 3b and 4 Category: physical mechanical testing material testing electromagnetic compatibility Accreditation: This proficiency test is not included in the scope of the accreditation. New proficiency testing |
|
October 2025 | Add to cart | |
Transient disturbances conducted along supply lines ISO 7637-2 - UN ECE R10 (6.9) Article Number: 2011248 |
October 2026 | Add to cart | ||
Voltage dips, short interruptions, voltage variations immunity IEC 61000-4-11 Parameters (quantitative): Amlitude before Dip - Minimum value [Vrms], Amplitude during Dip (0 % / 0 V / 1 cycle) - Mean value [Vrms], Amplitude during Dip (40 % / 92 V / 10 cycles) - Mean value [Vrms], Amplitude during Dip (70 % / 161 V / 25 cycles) - Mean value [Vrms], Amplitude during Dip (0 % / 0 V / 250 cycles) - Mean value [Vrms], Amlitude after Dip - Minimum value [Vrms], Dip Length (0 % / 0 V / 1 cycle) - Mean value [ms], Dip Length (40 % / 92 V / 10 cycles) - Mean value [ms], Dip Length (70 % / 161 V / 25 cycles) - Mean value [ms], Dip Length (0 % / 0 V / 250 cycles) - Mean value [ms] Article Number: 2011063 Description: The EMC test object consists of a tabletop unit with various supply connection options suitable for the specific task, e.g. 230V / 50 Hz, 12 V DC, 28 V DC. Operation via an integrated touch display with intuitive user interface. Category: physical mechanical testing material testing electromagnetic compatibility Accreditation: This proficiency test is not included in the scope of the accreditation. additional test chambers or additional test places are charged with 50% of the proficiency testing price Is currently underway. Can still be booked. |
|
August 2025 | Add to cart |
Under certain circumstances, this parameter may not be available in the proficiency test.