Proficiency testing catalogue
Name | Planned shipping method | Start Date | ||
---|---|---|---|---|
Medical devices - ethylene oxide residues (ISO 10993-7) 1 Parameters (quantitative): ethylene oxide (CAS 75-21-8) [mg/kg], ethylene chlorohydrin (CAS 107-07-3) [mg/kg] Article Number: 2010375 Description: Extraction by simulated application (reference method) in water Category: chemical-physical testing medical devices medical devices Accreditation: This proficiency test is not included in the scope of the accreditation. Suitable laboratory equipment is required for participation in the proficiency testing schemes. |
|
September 2025 | Add to cart | |
Medical devices - ethylene oxide residues (ISO 10993-7) 1 Article Number: 2010375 |
September 2026 | Add to cart | ||
Medical devices - ethylene oxide residues (ISO 10993-7) 2 Parameters (quantitative): ethylene oxide (CAS 75-21-8) [mg/kg], ethylene chlorohydrin (CAS 107-07-3) [mg/kg] Article Number: 2010377 Description: Exhaustive extraction Category: chemical-physical testing medical devices medical devices Accreditation: This proficiency test is not included in the scope of the accreditation. Suitable laboratory equipment is required for participation in the proficiency testing schemes. |
|
September 2025 | Add to cart | |
Medical devices - ethylene oxide residues (ISO 10993-7) 2 Article Number: 2010377 |
September 2026 | Add to cart | ||
Medical devices - extractables & leachables Parameters (qualitative): identification of various extractables & leachables Parameters (quantitative): quantification of the identified extractables & leachables [µg/ml] Article Number: 2011169 Category: chemical-physical testing medical devices medical devices Accreditation: This proficiency test is not included in the scope of the accreditation. New parameter selection |
|
August 2025 | Add to cart | |
Medical devices - extractables & leachables Parameters (qualitative): identification of various extractables & leachables Article Number: 2011169 |
August 2026 | Add to cart | ||
Medical devices - extraction of elements (ISO 10993-12) Parameters (quantitative): calcium (Ca), phosphorus (P), magnesium (Mg), fluorine (F), manganese (Mn), chromium (Cr), Iodine (I), selenium (Se) Article Number: 2011159 Category: chemical-physical testing medical devices medical devices Accreditation: This proficiency test is not included in the scope of the accreditation. |
|
September 2025 | Add to cart | |
Medical devices - extraction of elements (ISO 10993-12) Article Number: 2011159 |
September 2026 | Add to cart | ||
Medical devices - extraction of metals (ISO 10993-12) Parameters (quantitative): zinc (Zn) [µg/l], nickel (Ni) [µg/l], cadmium (Cd) [µg/l], lead (Pb) [µg/l], copper (Cu) [µg/l], cobalt (Co) 1 [µg/l], chromium (Cr) 1 [µg/l], arsenic (As) 1 [µg/l] Article Number: 2010379 Description: Extraction of the samples with water Category: chemical-physical testing medical devices medical devices Accreditation: This proficiency test is not included in the scope of the accreditation. Suitable laboratory equipment is required for participation in the proficiency testing schemes. |
|
May 2025 | Add to cart | |
Medical devices - extraction of metals (ISO 10993-12) Article Number: 2010379 |
June 2026 | Add to cart | ||
Medical devices - gravim. determination extractables Parameters (quantitative): extractables (n-hexane) [mg/dm²], extractables (iso-propanol) [mg/dm²] Article Number: 2011168 Description: If you are interested in testing aqueous simulants, e.g. ethanol 10% or dist. Water, please have a look at our proficiency tests for global migration in the field of consumer goods. Category: chemical-physical testing medical devices medical devices Accreditation: This proficiency test is not included in the scope of the accreditation. |
|
June 2025 | Add to cart | |
Medical devices - gravim. determination extractables Article Number: 2011168 |
July 2026 | Add to cart | ||
Medical devices - in vitro eye irritation (OECD492b) Parameters (qualitative): in vitro eye irritation Article Number: 2011290 Description: With the SkinEthic Human Corneal Epithelium (HCE) Time-to-Toxicity (TTT) test the eye irritation shall be tested with a reconstructed human corneal epithelium (HCE) according to OECD492b. The samples should be classified according to UN GHS Cat. 1, Cat. 2 and No Cat. The samples are a simulated extract. The extraction of a medical device is not part of the proficiency test. Category: immunological, molecular biological and microbiological testing medical devices medical devices Accreditation: This proficiency test is not included in the scope of the accreditation. New proficiency testing |
|
September 2025 | Add to cart | |
Medical devices - in vitro eye irritation (OECD492b) Parameters (qualitative): in vitro eye irritation Article Number: 2011290 |
September 2026 | Add to cart | ||
Medical devices - in vitro skin irritation (ISO 10993-23) Parameters (qualitative): skin irritation Article Number: 2011286 Description: The samples are extracted in accordance with ISO 10993-23 under conditions specified by us. Irritation is tested with both the polar and the non-polar extract using the EpiDerm or the EpiSkin model. The viability determined using the MTT assay is tested qualitatively (pass / not pass). Category: immunological, molecular biological and microbiological testing medical devices medical devices Accreditation: This proficiency test is not included in the scope of the accreditation. New proficiency testing |
|
October 2025 | Add to cart | |
Medical devices - in vitro skin irritation (ISO 10993-23) Parameters (qualitative): skin irritation Article Number: 2011286 |
October 2026 | Add to cart | ||
Medical devices - in vitro skin sensitisation (OECD 442D,KeratinoSens) Parameters (qualitative): skin sensitisation Article Number: 2011288 Description: The activation of keratinocytes is to be investigated using the ARE-Nrf2 luciferase KeratinoSens test method (OECD 442D Appendix IA). The samples are a simulated extract. The extraction of a medical device is not part of the proficiency test. Category: immunological, molecular biological and microbiological testing medical devices medical devices Accreditation: This proficiency test is not included in the scope of the accreditation. New proficiency testing |
|
December 2025 | Add to cart | |
Medical devices - in vitro skin sensitisation (OECD 442D,KeratinoSens) Parameters (qualitative): skin sensitisation Article Number: 2011288 |
December 2026 | Add to cart | ||
Medical devices - in vitro skin sensitisation (OECD 442E, h-CLAT) Parameters (qualitative): skin sensitisation, CD86, CD54 Article Number: 2011289 Description: The activation of the dendritic cells is to be investigated using the Human Cell Line Activation Test (h-CLAT) (OECD 442E, ANNEX 1). The samples are a simulated extract. The extraction of a medical device is not part of the proficiency test. Category: immunological, molecular biological and microbiological testing medical devices medical devices Accreditation: This proficiency test is not included in the scope of the accreditation. New proficiency testing |
|
December 2025 | Add to cart | |
Medical devices - in vitro skin sensitisation (OECD 442E, h-CLAT) Parameters (qualitative): skin sensitisation, CD86, CD54 Article Number: 2011289 |
December 2026 | Add to cart |
Unter Umständen kann es vorkommen, dass dieser Parameter im Ringversuch nicht zur Verfügung steht.